PURGE SOLENOID VALVE INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]
id0116zb800900
Airflow Inspection
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].)
2. Remove the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
3. Inspect airflow between the ports under the following conditions.
 ac5wzw00002826 
 | 
| 
 Measured condition  | 
 Continuity between ports A—B  | 
|---|---|
| 
 When voltage is not applied between terminals A and B 
 | 
 No airflow 
 | 
| 
 When voltage is applied between terminals A and B 
 | 
 Airflow detected 
 |