PURGE SOLENOID VALVE INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]


id0116zb800900


Airflow Inspection

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].)

2.  Remove the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].)

3.  Inspect airflow between the ports under the following conditions.

ac5wzw00002826

Measured condition

Continuity between ports A—B

When voltage is not applied between terminals A and B
No airflow
When voltage is applied between terminals A and B
Airflow detected

•  If not as specified, replace the purge solenoid valve. (See PURGE SOLENOID VALVE REMOVAL/INSTALLATION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].)