i-stop WARNING ALARM [SKYACTIV-G 2.0, SKYACTIV-G 2.5]
id0140g2300500
Purpose
Function
ac5wzn00001422
|
Construction
Operation
1. The instrument cluster receives (1) the i-stop warning alarm request signal from the PCM.
2. The instrument cluster microcomputer turns the transistor on (2) based on the i-stop warning alarm request signal.
3. When the transistor turns on, a ground circuit with the alarm is established and the alarm sounds (3).
am2zzn00003438
|
Fail-safe