AIRFLOW MODE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]


id0740a2801700

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)(See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].)(See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].)

2.  Remove the glove compartment. (See GLOVE COMPARTMENT REMOVAL/INSTALLATION.)

3.  Remove the airflow mode actuator. (See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)

4.  Apply battery positive voltage and connect the ground to the airflow mode actuator terminals as indicated in the table below and verify the operation condition.

B+ Terminal

Ground Terminal

Operation

D
F
DEFROSTER → VENT
F
D
VENT → DEFROSTER

ac5uuw00001197

5.  Verify that the resistance between terminals B and C, C and A matches the airflow mode actuator operation as shown in the graph.

am3zzw00019381

•  If the operation condition and resistance are not normal, replace the airflow mode actuator. (See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)(See AIRFLOW MODE ACTUATOR REMOVAL/INSTALLATION [FULL-AUTO AIR CONDITIONER].)