DTC U2300:56 [INSTRUMENT CLUSTER]
id0902e8016900
| Description | Instrument cluster configuration error | 
|---|---|
| Detection condition | •  Instrument cluster configuration error (incorrect value write) detected. | 
| Fail-safe function | Not applicable | 
| Possible cause | •  Instrument cluster configuration error •  Instrument cluster malfunction | 
| System wiring diagram | Not applicable | 
Diagnostic Procedure
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | PERFORM INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA) •  Using the M-MDS, perform the instrument cluster configuration (using As-Built data).
 •  Clear the DTC for the instrument cluster using the M-MDS.
 •  Retrieve the instrument cluster DTCs using the M-MDS.
 •  Is the same DTC displayed? | Yes | Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step. | 
| No | Go to Step 3. | ||
| 2 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED •  Clear the DTC for the instrument cluster using the M-MDS.
 •  Retrieve the instrument cluster DTCs using the M-MDS.
 •  Is the same DTC displayed? | Yes | Repeat the inspection from Step 1. •  If the malfunction recurs, replace the instrument cluster.
 Go to the next step. | 
| No | Go to the next step. | ||
| 3 | VERIFY IF OTHER DTCs DISPLAYED •  Are any other DTCs displayed? | Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. | 
| No | DTC troubleshooting completed. | ||