KEYLESS RECEIVER INSPECTION
id091400514400
WGN
1. Remove the following parts:
2. Pull back the trunk side upper trim (RH) to a position which allows for the removal of the keyless receiver. (See TRUNK SIDE UPPER TRIM REMOVAL/INSTALLATION.)
3. Pull back the trunk side trim (RH) to a position which allows for the removal of the keyless receiver. (See TRUNK SIDE TRIM REMOVAL/INSTALLATION.)
4. Remove the keyless receiver with the connector still connected. (See KEYLESS RECEIVER REMOVAL/INSTALLATION.)
5. Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).
Terminal Voltage Table (Reference)
ac5jjw00000234
|
Terminal |
Signal name |
Connected to |
Measurement conditions |
Voltage (V) |
Inspection item(s) |
---|---|---|---|---|---|
A
|
Power supply
|
Start stop unit
|
Under any condition
|
Approx. 5
|
Start stop unit
|
B
|
DATA
|
Start stop unit
|
Because this terminal is for communication, determination using terminal voltage inspection is not possible.
|
Start stop unit
|
|
D
|
GND
|
Body ground
|
Under any condition
|
1.0 or less
|
Ground
|
4SD
1. Remove the following parts:
2. Remove the keyless receiver with the connector still connected. (See KEYLESS RECEIVER REMOVAL/INSTALLATION.)
3. Verify that the voltages of each of the terminals are as indicated in the terminal voltage table (reference).
Terminal Voltage Table (Reference)
ac5jjw00000234
|
Terminal |
Signal name |
Connected to |
Measurement conditions |
Voltage (V) |
Inspection item(s) |
---|---|---|---|---|---|
A
|
Power supply
|
Start stop unit
|
Under any condition
|
Approx. 5
|
Start stop unit
|
B
|
DATA
|
Start stop unit
|
Because this terminal is for communication, determination using terminal voltage inspection is not possible.
|
Start stop unit
|
|
D
|
GND
|
Body ground
|
Under any condition
|
1.0 or less
|
Ground
|