HAZARD WARNING SWITCH INSPECTION
id091800803100
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)
2. Remove the following parts:
3. Verify that the continuity between the hazard warning switch terminals is as indicated in the table.
am6zzw00008069
|
am6zzw00008070
|
4. Apply battery voltage to hazard warning switch terminal A, and connect terminal B to ground.
am6zzw00014021
|
5. Verify that the LED illuminates.