AUTO LEVELING SENSOR INSPECTION
id091800805600
1. Remove the auto leveling sensor. (See AUTO LEVELING SENSOR REMOVAL/INSTALLATION.)
2. Prepare three dry cell batteries (1.5 V).
3. Connect the three dry cell batteries in a series.
am6zzw00008136
|
4. Connect the positive pole of the dry cell battery to auto leveling sensor terminal C, and the negative pole to terminal A.
am6zzw00012791
|
5. Connect the tester as shown in the figure with approx. 4.5 V of voltage applied between auto leveling sensor terminals A and C, and measure the voltage at auto leveling sensor terminal B.
am6zzw00012792
|
6. When slowly moving the auto leveling sensor link up and down, verify that the voltage fluctuates linearly between 0.5—4.5 V as shown in the figure.
am6zzw00008139
|