i-stop OFF SWITCH INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5]
id0140g2888900
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
2. Remove the cluster switch. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)
3. Verify that the resistance between cluster switch terminals B and G is as indicated in the table.
am6zzw00015292
|
am6zzw00014977
|
4. Apply battery positive voltage to cluster switch terminal J, and connect terminal I to ground.
am6zzw00012056
|
5. Verify that the LED illuminates.