i-stop OFF SWITCH INSPECTION [SKYACTIV-D 2.2]


id0140z7888900

1.  Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-D 2.2].)

2.  Remove the cluster switch. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)

3.  Verify that the resistance between cluster switch terminals B and C is as indicated in the table.

am6zzw00014976
am6zzw00014977

•  If the resistance can be verified as indicated in the table, go to the next step.
•  If not as indicated in the table, replace the cluster switch. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)

4.  Apply battery positive voltage to cluster switch terminal J, and connect terminal I to ground.

am6zzw00008624

5.  Verify that the LED illuminates.

•  If the LED does not illuminate, replace the cluster switch. (See CLUSTER SWITCH REMOVAL/INSTALLATION.)