UP SWITCH INSPECTION [FW6A-EL]
id0517h1600500
Continuity Inspection
1. Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].) (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5 (WITHOUT i-stop)].)
2. Remove the following parts:
3. Disconnect the selector lever component connector.
ac5uuw00003544
|
4. Verify that the continuity between selector lever component terminals C and J.
am6zzw00012081
|
Up switch specification
Test condition |
Continuity |
---|---|
Selector lever is in the M position (+) side position.
|
Continuity
|
Selector lever is not in the M position (+) side position.
|
No continuity
|