REFRIGERANT PRESSURE SENSOR INSPECTION [MANUAL AIR CONDITIONER]
id0740a2817400
SKYACTIV-G 2.0, SKYACTIV-G 2.5
1. Install the manifold gauge.
2. Verify the high-pressure side reading of the manifold gauge.
3. Measure the terminal voltage at PCM terminal 2BB, 2AX and 2AJ.
4. Using the graph below, measure and verify the terminal voltage at 2AX.
5. Follow the PCM inspection when measuring the other terminal voltages. (See PCM INSPECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5].)
ac5wzw00002773
|
SKYACTIV-D 2.2
1. Install the manifold gauge.
2. Verify the high-pressure side reading of the manifold gauge.
3. Measure the terminal voltage at PCM terminal 2BB, 2BH and 2BD.
4. Using the graph below, measure and verify the terminal voltage at 2BH.
5. Follow the PCM inspection when measuring the other terminal voltages. (See PCM INSPECTION [SKYACTIV-D 2.2].)
ac5wzw00002774
|