DTC TABLE [CLIMATE CONTROL UNIT (FULL-AUTO AIR CONDITIONER)]
id0702k2801700
| 
 DTC No.  | 
 Warning/indicator light  | 
 System malfunction location  | 
 Fail-safe function  | 
 Drive cycle  | 
 Self test type*1  | 
 Memory function  | 
 Page  | 
|---|---|---|---|---|---|---|---|
| 
 B1081:71 
 | 
 — 
 | 
 •  Driver-side air mix actuator motor lock (L.H.D.) 
•  Passenger-side air mix actuator motor lock (R.H.D.) 
 | 
 X 
 | 
 — 
 | 
 C 
 | 
 X 
 | 
|
| 
 B1082:71 
 | 
 — 
 | 
 •  Passenger-side air mix actuator motor lock (L.H.D.) 
•  Driver-side air mix actuator motor lock (R.H.D.) 
 | 
 X 
 | 
 — 
 | 
 C 
 | 
 X 
 | 
|
| 
 B1086:71 
 | 
 — 
 | 
 Airflow mode actuator motor lock 
 | 
 X 
 | 
 — 
 | 
 C 
 | 
 X 
 | 
|
| 
 B10FB:71*2 
 | 
 — 
 | 
 Air intake actuator motor lock 
 | 
 X 
 | 
 — 
 | 
 C 
 | 
 X 
 | 
|
| 
 B11F0:12*2 
 | 
 — 
 | 
 Air intake actuator (potentiometer) circuit short to power supply 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B11F0:13*2 
 | 
 — 
 | 
 Air intake actuator (potentiometer) circuit open 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B11F5:86*3 
 | 
 — 
 | 
 Invalid data (humidity sensor temperature) received from humidity sensor 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1A61:11 
 | 
 — 
 | 
 Cabin temperature sensor circuit short to ground 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1A61:13 
 | 
 — 
 | 
 Cabin temperature sensor circuit open 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1A63:12 
 | 
 — 
 | 
 Solar radiation sensor (RH) circuit short to power supply 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1A63:13 
 | 
 — 
 | 
 Solar radiation sensor (RH) circuit open 
 | 
 X 
 | 
 — 
 | 
 D 
 | 
 X 
 | 
|
| 
 B1A64:12 
 | 
 — 
 | 
 Solar radiation sensor (LH) circuit short to power supply 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1A64:13 
 | 
 — 
 | 
 Solar radiation sensor (LH) circuit open 
 | 
 X 
 | 
 — 
 | 
 D 
 | 
 X 
 | 
|
| 
 B1A69:86*3 
 | 
 — 
 | 
 Invalid data (relative humidity) received from humidity sensor 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1B71:11 
 | 
 — 
 | 
 Evaporator temperature sensor circuit short to ground 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1B71:13 
 | 
 — 
 | 
 Evaporator temperature sensor circuit open 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1C1A:11 
 | 
 — 
 | 
 •  Driver-side air mix actuator (potentiometer) circuit short to ground (L.H.D.) 
•  Passenger-side air mix actuator (potentiometer) circuit short to ground (R.H.D.) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1C1A:13 
 | 
 — 
 | 
 •  Driver-side air mix actuator (potentiometer) circuit open (L.H.D.) 
•  Passenger-side air mix actuator (potentiometer) circuit open (R.H.D.) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1C1B:11 
 | 
 — 
 | 
 •  Passenger-side air mix actuator (potentiometer) circuit short to ground (L.H.D.) 
•  Driver-side air mix actuator (potentiometer) circuit short to ground (R.H.D.) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1C1B:13 
 | 
 — 
 | 
 •  Passenger-side air mix actuator (potentiometer) circuit open (L.H.D.) 
•  Driver-side air mix actuator (potentiometer) circuit open (R.H.D.) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1C1C:11 
 | 
 — 
 | 
 Airflow mode actuator (potentiometer) circuit short to ground 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 B1C1C:13 
 | 
 — 
 | 
 Airflow mode actuator (potentiometer) circuit open 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U0010:88 
 | 
 — 
 | 
 Unit communication error (MS-CAN) 
 | 
 — 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U0155:00 
 | 
 — 
 | 
 Communication error with instrument cluster 
 | 
 X 
 | 
 — 
 | 
 C 
 | 
 X 
 | 
|
| 
 U0423:68 
 | 
 — 
 | 
 Invalid data received from Instrument cluster 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U200D:11 
 | 
 — 
 | 
 Climate control unit circuit voltage (+5V) circuit short to ground 
 | 
 — 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U210A:86*3 
 | 
 — 
 | 
 Invalid data (windshield temperature) received from humidity sensor 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U2300:54 
 | 
 — 
 | 
 Configuration error (data not received) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U2300:55 
 | 
 — 
 | 
 Configuration error (not configured) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 — 
 | 
|
| 
 U2300:56 
 | 
 — 
 | 
 Configuration error (ineffective/non-interchangeable data read) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U2300:64 
 | 
 — 
 | 
 Configuration error (error value read) 
 | 
 X 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U3003:16 
 | 
 — 
 | 
 Climate control unit power supply circuit voltage below threshold (9.98 V or less) 
 | 
 — 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U3003:17 
 | 
 — 
 | 
 Climate control unit power supply circuit voltage above threshold (16.21 V or more) 
 | 
 — 
 | 
 — 
 | 
 C, D 
 | 
 X 
 | 
|
| 
 U300E:13 
 | 
 — 
 | 
 Climate control unit power supply circuit open (IG1 or IG2) 
 | 
 — 
 | 
 — 
 | 
 C, D 
 | 
 X 
 |