DTC U200D:11 [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]
id0702k3736600
With Single Type Climate Control Unit
| 
 System malfunction location  | 
 •  Climate control unit circuit voltage (+5V) circuit short to ground 
 | 
|---|---|
| 
 Detection condition 
 | 
 •  Malfunction in wiring harness between climate control unit circuit voltage (+5V) and each actuator 
 | 
| 
 Fail-safe function 
 | 
 Not applicable 
 | 
| 
 Possible cause 
 | 
 •  Connector or terminal malfunction 
•  Each actuator malfunction 
•  Short to ground in wiring harness between the following terminals: 
 L.H.D. 
 R.H.D. 
•  Climate control unit malfunction 
 | 
![]()  | 
|
Diagnostic procedure
| 
 STEP  | 
 INSPECTION  | 
 ACTION  | 
|
|---|---|---|---|
| 
 1 
 | 
 VERIFY CLIMATE CONTROL UNIT CONNECTOR CONDITION 
•  Switch the ignition off. 
•  Disconnect the negative battery cable.
 
•  Disconnect the climate control unit connectors.
 
•  Inspect the connector and terminals (corrosion, damage, pin disconnection). 
•  Are the connector and terminals normal? 
 | 
 Yes 
 | 
 Go to the next step. 
 | 
| 
 No 
 | 
 Repair/replace the connector or terminal. 
After repair procedure, go to Step 5. 
 | 
||
| 
 2 
 | 
 VERIFY CONNECTOR CONDITION 
•  Disconnect the following each actuator connectors. 
 •  Inspect the connector and terminals (corrosion, damage, pin disconnection). 
•  Are the connector and terminals normal? 
 | 
 Yes 
 | 
 Go to the next step. 
 | 
| 
 No 
 | 
 Replace the malfunctioning part. 
After replace procedure, go to Step 5. 
 | 
||
| 
 3 
 | 
 INSPECT EACH ACTUATOR 
•  Inspect the following each actuator. 
 •  Is it normal? 
 | 
 Yes 
 | 
 Go to the next step. 
 | 
| 
 No 
 | 
 Replace the malfunctioning actuator. 
After replace procedure, go to Step 5. 
 | 
||
| 
 4 
 | 
 INSPECT EACH ACTUATOR CIRCUIT FOR SHORT TO GROUND 
•  Inspect for continuity between the following terminal (wiring harness-side) and body ground: 
 •   Is there continuity? 
 | 
 Yes 
 | 
 Refer to the wiring diagram and verify whether or not there is a common connector between climate control unit terminal and each actuator terminal. 
If there is a common connector: 
•  Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground. 
•  Repair or replace the malfunctioning part. 
If there is no common connector: 
•  Repair or replace the wiring harness which has a short to ground. 
Go to the next step. 
 | 
| 
 No 
 | 
 Go to the next step. 
 | 
||
| 
 5 
 | 
 VERIFY THAT SAME DTC IS NOT OUTPUT AGAIN 
•  Reconnect the disconnected connectors. 
•  Connect the negative battery cable.
 
•  Clear the DTC from the climate control unit memory using the M-MDS.
 
•  Perform the climate control unit DTC inspection using the M-MDS.
 
•  Is the same DTC displayed? 
 | 
 Yes 
 | 
 Repeat the inspection from Step 1. 
•  If the malfunction recurs, replace the climate control unit.
 
Go to the next step. 
 | 
| 
 No 
 | 
 Go to the next step. 
 | 
||
| 
 6 
 | 
 VERIFY THAT NO OTHER DTCs ARE PRESENT 
•  Verify other DTCs displayed. 
•  Are any other DTCs displayed? 
 | 
 Yes 
 | 
 Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. 
 | 
| 
 No 
 | 
 DTC troubleshooting completed. 
 | 
||