DTC TABLE [CLIMATE CONTROL UNIT (MANUAL AIR CONDITIONER)]
id0702k3801700
DTC No. |
Warning/indicator light |
System malfunction location |
Fail-safe function |
Drive cycle |
Self test type*1 |
Memory function |
Page |
---|---|---|---|---|---|---|---|
B1086:71
|
—
|
Airflow mode actuator motor lock
|
X
|
—
|
C
|
X
|
|
B10FB:71*2
|
—
|
Air intake actuator motor lock
|
X
|
—
|
C
|
X
|
|
B11F0:12*2
|
—
|
Air intake actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B11F0:13*2
|
—
|
Air intake actuator (potentiometer) circuit open
|
X
|
—
|
C, D
|
X
|
|
B11F5:86*3
|
—
|
Invalid data (humidity sensor temperature) received from humidity sensor
|
X
|
—
|
C, D
|
X
|
|
B13AA:71
|
—
|
Air mix actuator motor lock
|
X
|
—
|
C
|
X
|
|
B13AB:12
|
—
|
Air mix actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B13AB:13
|
—
|
Air mix actuator (potentiometer) circuit open
|
X
|
—
|
C, D
|
X
|
|
B1A69:86*3
|
—
|
Invalid data (relative humidity) received from humidity sensor
|
X
|
—
|
C, D
|
X
|
|
B1B71:11
|
—
|
Evaporator temperature sensor circuit short to ground
|
X
|
—
|
C, D
|
X
|
|
B1B71:13
|
—
|
Evaporator temperature sensor circuit open
|
X
|
—
|
C, D
|
X
|
|
B1C1C:12
|
—
|
Airflow mode actuator (potentiometer) circuit short to power supply
|
X
|
—
|
C, D
|
X
|
|
B1C1C:13
|
—
|
Airflow mode actuator (potentiometer) circuit open
|
X
|
—
|
C, D
|
X
|
|
U0010:88
|
—
|
Unit communication error (MS-CAN)
|
—
|
—
|
C
|
X
|
|
U0155:00
|
—
|
Communication error with instrument cluster
|
X
|
—
|
C, D
|
X
|
|
U0423:68
|
—
|
Invalid date received from Instrument cluster
|
X
|
—
|
C, D
|
X
|
|
U200D:11
|
—
|
Climate control unit circuit voltage (+5V) circuit short to ground
|
—
|
—
|
C, D
|
X
|
|
U210A:86*3
|
—
|
Invalid data (windshield temperature) received from humidity sensor
|
X
|
—
|
C, D
|
X
|
|
U2300:54
|
—
|
Configuration error (data not received)
|
X
|
—
|
C, D
|
X
|
|
U2300:55
|
—
|
Configuration error (not configured)
|
X
|
—
|
C, D
|
—
|
|
U2300:56
|
—
|
Configuration error (ineffective/non-interchangeable data read)
|
X
|
—
|
C, D
|
X
|
|
U2300:64
|
—
|
Configuration error (error value read)
|
X
|
—
|
C, D
|
X
|
|
U3003:16
|
—
|
Climate control unit power supply circuit voltage below threshold (10.00 V or less)
|
—
|
—
|
C, D
|
X
|
|
U3003:17
|
—
|
Climate control unit power supply circuit voltage above threshold (17.30 V or more)
|
—
|
—
|
C, D
|
X
|
|
U300E:13
|
—
|
Climate control unit power supply circuit open (IG2)
|
—
|
—
|
C, D
|
X
|